Wenzhou Kaixin Metal Co.,Ltd

Wenzhou Kaixin Metal Co., Ltd.

Whatarethestepsforpickling304stainlesssteelpipes?Manufactureinchina

Rustfrit stålrør

Operation steps for pickling 304 rustfri stålrør.

1. Pipe ready

2. Chemical degreasing

(1) Den kemiske oliefjernelse anvender nedsænkningsmetoden i tanken, og oliefjerningstanken er lavet af stålplade, med PVC eller polyethylen lagt på indervæggen.

(2) Anvendelser til kemisk affedtningsbehandling 12-15% salpetersyre (efter volumen) ved en temperatur på 40 ℃ til 60 ℃ for 2-4 timer.

(3) Ved iblødsætning 304 rustfri stålrør i tanken, være opmærksom på deres placering for at undgå at efterlade luft inde i rørene.

(4) Under iblødsætningsprocessen, røret skal flyttes op og ned eller vendes, and the internal solution should be constantly replaced to improve the effect. If necessary, remove the tube, rinse with water and gas, and then soak.

(5) Chemical degreasing until the surface of the pipe fittings is completely wet.

3. Hot water flushing

(1) Remove the 304 stainless steel sanitary pipe after oil removal from the oil removal tank and soak it in a hot water tank at around 40 ℃~60 ℃ for rinsing for 5-20 minutes.

(2) The hot water tank is made of steel plate, and the inner wall is covered with polyvinyl chloride or polyethylene.

(3) The chloride ion content in water is less than 25ppm.

4. Rinse with water.

(1) Use pressure water (pressure P ≥ 0, 1Mpa) to rinse the pipes that have been washed with water.

(2) The chloride ion content in water is less than 25ppm.

5. Passivation

(1) Select the passivation solution formula and soaking time according to Tables 2 and 3.

(2) Produce passivation groove steel plates with acid resistant plastic on the inner walls.

(3) When soaking in the tank, pay attention to the placement to avoid air inside the tube.

(4) Under iblødsætningsprocessen, the pipe fittings should be moved up and down or flipped, and the internal solution should be constantly replaced to improve the effect. If necessary, the pipes should be removed, washed with water and gas, and then soaked.

6. Drying

After passivating the 304 stainless steel sanitary pipe, dry it with clean compressed air or nitrogen, and there must be sufficient time (at least 2 timer) for natural passivation in the air.

7. Inspection

After passivation of 304 stainless steel sanitary pipes, self inspection and mutual inspection should be conducted, and then submitted to quality inspection personnel for acceptance as required.

8. Protection

(1) Pipe fittings that require painting on the outer surface shall be painted according to the painting requirements.

(2) The pipes that pass the inspection shall be sealed with plastic plugs, wrapped with three proof cloth for protection, and marked.

+86-577-85980211